WELL LOGS · UNITED STATES · ONE ROW PER LOG
Well logs within 2 mi of API 42-467-01026
Well logs loaded into Petrora from the regulators' log indexes, newest received first: what each measures, whether it is a digital LAS file or an image, the interval filed for it, and the formations it spans by the well's own tops. Loaded so far for Texas; more states and data sources will follow. Petrora lists these logs; each well's page links to the regulator for the files.
Distances are to the nearest location on file for each well (a horizontal has several along its path), in miles. Locations are surface and path points as mapped, not bottom-hole surveys.
13 LOG FILES ON 13 WELLS · A LOG'S LAS AND IMAGE IN ONE ROW · PAGE 1 OF 1
| Well | Distancemi | Logas described | Intervalft, as filed | Datereceived |
|---|---|---|---|---|
| Fruitvale Waterflood Unit #801HZ42-467-31114Van Zandt, TX · Jamex Inc. | 0.27 | COMBINATION: RESISTIVITY/NEUTRON/DENSITY POROSITYTIFF | 775 to 8,023 | Jan 12, 2011run Nov 29, 2007 |
| Fruitvale Waterflood Unit #90142-467-31117Van Zandt, TX · Jamex Inc. | 0.35 | RESISTIVITYTIFF | 798 to 8,848 | Nov 4, 2011run Sep 9, 2008 |
| Fruitvale Waterflood Unit #101HZ42-467-31128Van Zandt, TX · Jamex Inc. | 0.40 | COMBINATION: RESISTIVITY/NEUTRON/DENSITY POROSITYTIFF | 676 to 8,235 | Dec 23, 2013run Sep 29, 2010 |
| Fruitvale Waterflood Unit #60142-467-31139Van Zandt, TX · Jamex Inc. | 0.52 | COMBINATION: RESISTIVITY/NEUTRON/DENSITY POROSITYTIFF | 756 to 8,896 | Dec 8, 2014run Nov 11, 2011 |
| Fruitvale Waterflood Unit #20142-467-31137Van Zandt, TX · Jamex Inc. | 0.52 | COMBINATION: RESISTIVITY/NEUTRON/DENSITY POROSITYTIFF | 759 to 8,907 | Sep 16, 2014run Aug 30, 2011 |
| Fruitvale Waterflood Unit #1001HZ42-467-31124Van Zandt, TX · Jamex Inc. | 0.54 | COMBINATION: RESISTIVITY/NEUTRON/DENSITY POROSITYTIFF | 778 to 8,267 | Oct 8, 2012run Aug 28, 2009 |
| Fruitvale Waterflood Unit #120142-467-31120Van Zandt, TX · Jamex Inc. | 0.69 | RESISTIVITYTIFF | 754 to 8,921 | Oct 31, 2011run Oct 10, 2008 |
| Fruitvale Waterflood Unit #70142-467-31143Van Zandt, TX · Jamex Inc. | 0.81 | RESISTIVITYTIFF | 757 to 8,901 | Aug 13, 2015run Jul 1, 2012 |
| Fruitvale Waterflood Unit #140142-467-31144Van Zandt, TX · Jamex Inc. | 0.89 | COMBINATION: RESISTIVITY/NEUTRON/DENSITY POROSITYTIFF | 714 to 9,170 | Dec 14, 2015run Nov 3, 2012 |
| Mullins #142-467-31118Van Zandt, TX · Jamex Inc. | 0.92 | RESISTIVITYTIFF | 635 to 9,015 | Aug 16, 2011run Nov 8, 2008 |
| Fruitvale Waterflood Unit #110142-467-31148Van Zandt, TX · Jamex Inc. | 0.92 | RESISTIVITYTIFF | 5,800 to 8,908 | Dec 8, 2015run Nov 22, 2012 |
| Fruitvale Waterflood Unit #130142-467-31156Van Zandt, TX · Jamex Inc. | 1.13 | RESISTIVITYTIFF | 762 to 8,912 | Sep 14, 2016run Jun 1, 2013 |
| Stephens #142-467-31088Van Zandt, TX · Randall Exploration LLC | 1.97 | COMBINATION: RESISTIVITY/NEUTRON/DENSITY POROSITYTIFF | 5,346 to 14,356 | Jul 18, 2008run Dec 9, 2006 |
About this data
Well logs loaded into Petrora from the regulators' log indexes, so far for Texas, with more states and data sources to follow; not necessarily every log that exists. These are the logs loaded into Petrora from the Railroad Commission's inventories, not necessarily every log run on the well. The RRC holds the files; each opens from its log search for the well. The kind is the RRC's description of the log; the interval is the one filed for it. A formation is spanned where the log's filed interval overlaps it in the well's own formation tops; both are measured depths as filed, so a horizontal's lateral is counted in the formation it ends in. Kinds are read from the regulator's description of each log, not from its curves. The date is when the log entered the RRC's imaged log database; a run date is shown where the index gives a different one (mostly logs before 2017: since digital filing began that year, the index gives the filing date for both). Nothing is estimated.
Developers: this page as JSON is GET /v1/data/logs, documented in the API reference.